350W Single-output Enclosed Type Power Supply LRS-350
INQUIRY
?AC input range selectable by switch
?Withstand 300VAC surge input for 5 second
?Protections: Short circuit/ Overload/ Over voltage/ Over temperature
?Cooling by free air convection
?1J low profile
?Withstand 5G vibration test
?LED indicator for power on
?No load power consumption<0.75W
?100% full load burn-in test
?High operating temperature up to 70℃
?Operating altitude up to 5000 meters( Note. 8)
?High efficiency, long life and high reliability
?3years warranty
●Industrial automation machinery
●Industrial control system
●Mechanical and electrical equipment
●Electronic instruments, equipments or apparatus
OUTPUT
|
|||||||
Model
|
LRS-350-3.3
|
LRS-350-5
|
LRS-350-12
|
LRS-350-15
|
LRS-350-24
|
LRS-35-36
|
LRS-35-48
|
DC Voltage
|
3.3V
|
5V
|
12V
|
15V
|
24V
|
36V
|
48V
|
Rated Current
|
60A
|
60A
|
29A
|
23.2A
|
14.6A
|
9.7A
|
7.3A
|
Current Range
|
0~60A
|
0~60A
|
0~29A
|
0~23.2A
|
0~14.6A
|
0~9.7A
|
0~7.3A
|
Rated Power
|
198W
|
300W
|
348W
|
348W
|
350.4W
|
349.2W
|
350.4W
|
Ripple & Noise
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
Voltage Adj. Range
|
2.97~3.6V
|
4.5 ~ 5.5V
|
10~ 13.8V
|
13.5~18V
|
21.6~28.8V
|
32.4~39.6V
|
43.2~52.8V
|
Voltage Tolerance
|
±4.0%
|
±3.0%
|
±1.5%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load Regulation
|
±2.5%
|
±2.0%
|
±1.0%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Setup, Rise Time
|
1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load
|
||||||
Hold Up Time
|
16ms/230VAC 12ms/115VAC at full load
|
||||||
INTPUT
|
|||||||
Voltage Range
|
90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC)
|
||||||
Frequency Range
|
47 ~ 63Hz
|
||||||
Efficiency
|
79.50%
|
83.50%
|
85%
|
86%
|
88%
|
88.50%
|
89%
|
AC Current
|
6.8A/115VAC 3.4A/230VAC
|
||||||
Inrush Current
|
60A/115VAC 60A/230VAC
|
||||||
Leakage Current
|
<2mA / 240VAC
|
||||||
PROTECTION
|
|||||||
Over Load
|
110 ~ 140% rated output power
|
||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed
|
|||||||
Over Voltage
|
3.8~4.45V
|
5.75~6.75V
|
13.8 ~ 16.2V
|
18~21V
|
28.8~33.6V
|
41.4~46.8V
|
55.2~ 64.8V
|
Protection type: Hiccup mode, recovers automatically after fault condition is removed
|
|||||||
Over temperature
|
Hiccup mode, recovers automatically after fault condition is removed
|
||||||
ENVIRONMENT
|
|||||||
Working Temp.
|
-20 ~ +70℃ (Refer to “derating curve”)
|
||||||
Working Humidity
|
20 ~ 90% RH non-condensing
|
||||||
Storage Temp.,
|
-40 ~ +85℃, 10 ~ 95% RH
|
||||||
Temp. Coefficient
|
±0.03%/℃ (0 ~ 50℃)
|
||||||
Vibration
|
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
|
||||||
SAFETY
|
|||||||
Safety Standards
|
UL60950-1 approved
|
||||||
Withstand Voltage
|
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
|
||||||
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
|
||||||
OTHERS
|
|||||||
Dimension
|
215*115*30mm (L*W*H)
|
||||||
Weight
|
0.76Kg
|
||||||
Packing
|
15pcs/carton/12.4kg/0.78CUFT
|